ru en

Tecnofoam

TECNOFOAM is a range of polyurethane foams specially designed for projection and injection in residential, commercial and industrial construction projects. The range of densities available is designed to cover all of your specific requirements.
TECNOFOAM G-2060 HFO
TECNOFOAM G-2060 HFO TECNOFOAM G-2060 HFO

Spray polyurethane foam (SPF) system for thermal insulation(applied density ±60 kg/m³)

TECNOFOAM G-2060 HFO spray polyurethane foam system for thermal insulation is specifically formulated to apply foam with applied density around (±52~62 kg/m³). Its application has to be done by the specific spray equipment. The blowing agent is HFO gas.

It has CE marking on the basis of a statement made DoP Declaration of Performance (DoP) conforms to the UE 305/2011 regulation.

More
TECNOFOAM G-2040 HFO
TECNOFOAM G-2040 HFO TECNOFOAM G-2040 HFO

Spray polyurethane foam (SPF) system for thermal insulation(applied density ±40 kg/m³)

TECNOFOAM G-2040 HFO spray polyurethane foam system for thermal insulation is specifically formulated to apply foam with applied density around (±40~46 kg/m³). Its application has to be done by the specific reactor equipment. The blowing agent is HFO gas.

It has CE marking on the basis of a statement made DoP Declaration of Performance (DoP) conforms to the UE 305/2011 regulation.

More
TECNOFOAM G-2035 HFO
TECNOFOAM G-2035 HFO TECNOFOAM G-2035 HFO

Spray polyurethane foam (SPF) system for thermal insulation(applied density ±35 kg/m³)

TECNOFOAM G-2035 HFO spray polyurethane foam system for thermal insulation is specifically formulated to apply foam with applied density around (±34~38 kg/m³). Its application has to be done by the specific reactor equipment. The blowing agent is HFO gas.

It has CE marking on the basis of a statement made DoP Declaration of Performance (DoP) conforms to the UE 305/2011 regulation.

More
TECNOFOAM G-2008
TECNOFOAM G-2008 TECNOFOAM G-2008

Spray polyurethane foam (SPF) system for thermal insulation (applied density ±8 kg/m³)

TECNOFOAM G-2008 thermal insulation open cell polyurethane system TECNOFOAM G-2008 is specifically formulated to apply low density foam (±8~10 kg/m³). Its application has to be done by the specific spray equipment. The blowing agent is water

More
TECNOFOAM G-2025
TECNOFOAM G-2025 TECNOFOAM G-2025

Spray polyurethane foam (SPF) system for thermal insulation(applied density ±25 kg/m³)

TECNOFOAM G-2025 polyurethane system for thermal insulation, is specifically formulated to apply foam with applied density around (±25~28 kg/m³). Its application has to be done by the specific spray equipment.The blowing agent is water.

More
TECNOFOAM I-2035
TECNOFOAM I-2035 TECNOFOAM I-2035

Polyurethane foam for injection (applied density ±35 kg/m³)

TECNOFOAM I-2035 is a system composed of two components (polyol and isocyanate) produces polyurethane foam of an applied density from 35 to 45 kg/m³ , is suitable for injection isolation application as on ducts , tubing, colds stores and rooms.

It contains HFO gas (Hydrofluoric-olefin). It doesn’t contain fluorinated gases.

More
TECNOFOAM G-2035
TECNOFOAM G-2035 TECNOFOAM G-2035

Spray polyurethane foam (SPF) system for thermal insulation(applied density ±35 kg/m³)

TECNOFOAM G-2035 polyurethane system for thermal insulation, is specifically formulated to apply foam with applied density around (±35~42 kg/m³). Its application has to be done by the specific reactor equipment. The blowing agent is water.

More
TECNOFOAM G-2040
TECNOFOAM G-2040 TECNOFOAM G-2040

Spray polyurethane foam (SPF) system for thermal insulation(applied density ±40 kg/m³)

TECNOFOAM G-2040 polyurethane system for thermal insulation, is specifically formulated to apply foam with applied density around (±40~50 kg/m³). Its application has to be done by the specific spray equipment. The blowing agent is water.

More
TECNOFOAM G-2040 FR
TECNOFOAM G-2040 FR TECNOFOAM G-2040 FR

Spray polyurethane foam (SPF) system for thermal insulation(applied density ±40 kg/m³). Fire reaction M1.

TECNOFOAM G-2040 FR (technically TECNOFOAM S-401) polyurethane system for thermal insulation, is specifically formulated to apply foam with applied density around (±40~50 kg/m³), and M1 fire reaction is requires. Its application has to be done by specific reactor equipment. The blowing agent is water.

More
TECNOFOAM I-2008
TECNOFOAM I-2008 TECNOFOAM I-2008

Polyurethane foam for injection (applied density ±12 kg/m³ )

TECNOFOAM I-2008 is a system composed of two components (polyol and isocyanate) produces polyurethane foam of an applied density from 12 to18 kg/m³ ,is suitable for acoustic isolation uses. The blowing agent is water

More
TECNOFOAM G-2050
TECNOFOAM G-2050 TECNOFOAM G-2050

Spray polyurethane foam (SPF) system for thermal insulation(applied density ±50 kg/m³)

TECNOFOAM G-2050 polyurethane system for thermal insulation, is specifically formulated to apply foam with applied density around (±50~60 kg/m³). Its application has to be done by the specific spray equipment. The blowing agent is water.

More

Main office

Barcelona (Spain)

Finlàndia 33, 08520. Les Franqueses del Vallès.
Telephone: (+34) 935 68 21 11

Office

Kishinev/Moldova

St. Andrey Doga, no. 2/1, office 3
Telephone: (+373 22) 601122, (+373) 69132905

Distributors

ALGERIA | SAUDI ARABIA | ARGENTINA | AUSTRIA | BAHRAIN | BELGIUM | BANGLADESH | BRAZIL | COLOMBIA | CHILE | CANADA | CAMEROON | BULGARIA | CZECH REPUBLIC | DOMINICAN REPUBLIC | ECUADOR | ESTONIA | FINLAND | FRENCH POLYNESIA | GEORGIA | GERMANY | GUADALUPE | HUNGARY | GUATEMALA | INDIA | IRELAND | ITALY | ISRAEL | KENYA | KUWAIT | LATVIA |LUXEMBOURG | MALAYSIA | MADAGASCAR | MARTINICA | MALT | MEXICO | MAURITIUS | LEBANON | MOLDOVA | MOROCCO | NETHERLANDS | NEW CALEDONIA | NORWAY | OMAN | PANAMA | PARAGUAY | PERU | PHILIPPINES | POLAND | PORTUGAL | QATAR | ROMANIA | SINGAPORE | SOUTH AFRICA | SLOVAKIA | SWEDEN | TUNISIA | TURKEY | UNITED KINGDOM | URUGUAY | UKRAINE | UNITED ARAB EMIRATES | RUSSIA